Estimation and Validation of Gefitinib by using Rp- High Performance Liquid Chromatography.

Hitler, Ningthoujam (2014) Estimation and Validation of Gefitinib by using Rp- High Performance Liquid Chromatography. Masters thesis, Cherraan`s College of Pharmacy, Coimbatore.

[img]
Preview
Text
Hitler Ningthoujam.pdf

Download (2MB) | Preview

Abstract

In the present work, RP-HPLC method has been developed for the quantitative estimation of Gefitinib in Pharmaceutical formulations. A rapid and sensitive RP-HPLC Method with UV detection (246 nm) for routine analysis of Gefitinib in Pharmaceutical formulation was developed using gradient pump (LC-10AT vp pump), The separations were achieved on a Agilents’s 5μ C18 (2) 100A, 250X4.6mm, column with UV detection at 246 nm. Chromatography was performed with mobile phase containing a mixture of 0.1% Triflouroacetic acid and Methanol (35:65 v/v) with flow rate 1 ml/min and retention time at 3.8 min. In the range of 5 -30μg/ml, the linearity of Gefitinib shows a correlation co-efficient of 0.999. The proposed method was validated by determining sensitivity, accuracy, precision, linearity, selectivity and system suitability parameters.

Item Type: Thesis (Masters)
Uncontrolled Keywords: Estimation; Gefitinib; Liquid Chromatography
Subjects: PHARMACY > Pharmaceutical Analysis
Depositing User: Ravindran C
Date Deposited: 27 Jul 2017 07:17
Last Modified: 06 Oct 2017 03:39
URI: http://repository-tnmgrmu.ac.in/id/eprint/2246

Actions (login required)

View Item View Item